Southland Sensing oxygen analyzers provide continuous oxygen measurement for heat treating, bright annealing, carburizing, carbonitriding, brazing, sintering, vacuum furnace backfill, and controlled atmosphere furnaces. Our analyzers help manufacturers verify furnace atmosphere integrity, detect air ingress, prevent oxidation and decarburization, and consistently produce high-quality metal components.
Controlled atmosphere heat treating relies on precise oxygen measurement to produce consistent metallurgical properties and high-quality surface finishes. Whether processing carbon steel, stainless steel, tool steel, nickel alloys, titanium, or powder metal components, even small amounts of oxygen entering the furnace atmosphere can cause oxidation, decarburization, scaling, discoloration, and reduced product quality.
Modern heat treating operations use nitrogen, argon, hydrogen, endothermic gas, dissociated ammonia, vacuum systems, or other protective atmospheres to prevent unwanted oxidation while achieving the desired mechanical properties. Continuous oxygen monitoring verifies atmosphere integrity, detects air ingress, confirms purge effectiveness, and helps maintain consistent furnace performance throughout every stage of the thermal process.
This application note examines the major heat treating processes—including carburizing, bright annealing, sintering, brazing, vacuum furnace backfill, and inert gas purging—and explains where oxygen analyzers are installed and which Southland Sensing analyzers are best suited for each application.
Почему важен мониторинг уровня кислорода: Continuous or intermittent oxygen monitoring helps verify atmosphere quality, detect air ingress, and protect both part metallurgy and process safety across critical thermal
Rugged wall-mount transmitter built for the production floor. Multiple input power options support direct integration with furnace control systems for steel production and continuous annealing lines.
1/4 DIN panel mount analyzer with a remote sensor housing, keeping electronics safely away from furnace heat. A common choice for metals treating, inert glovebox systems, and combustion control.
Same measurement performance in a compact housing. Configurable input power and sensor housing options make it well suited for sintering lines and skid-mounted thermal processing equipment.
✓ Настраиваемый дизайн
Engineered for explosive atmospheres. ATEX & IECEx certified — suited for furnace exhaust monitoring and thermal processing lines using flammable carrier gases such as hydrogen or endothermic gas.
⚠ ATEX · IECEx Certified
Accurate oxygen analysis in metals and heat treating applications depends not only on the analyzer itself, but also on the proper design of the sample handling system. Factors such as sample temperature, particulate content, pressure, and material compatibility can significantly impact measurement stability, response time, and overall analyzer performance.
A properly engineered sample system helps ensure that the analyzer receives a clean, stable, and representative gas sample under the correct operating conditions. Proper temperature reduction, filtration, and sample conditioning can often make the difference between a reliable oxygen measurement and inaccurate or unstable readings near a furnace environment.
Southland Sensing offers application support to help customers properly specify sample systems for demanding thermal processing applications. Contact the factory to discuss process conditions, gas composition, temperature, flow requirements, and hazardous-area considerations to ensure the analyzer system is properly configured for your installation.
Fixed ambient monitors should be installed at low-level points in any enclosed heat treating or furnace room where inert purge gases such as nitrogen or argon are used. Our monitors provide continuous room-air O₂ measurement with audible and visual alarms at user-configurable setpoints (typically 20.0% and 19.5% O₂).
Обратитесь к нашему Руководство по совместимости датчиков кислорода (O₂) чтобы подтвердить правильность выбора датчика для вашей модели анализатора и технологического процесса.
Yes. Our electrochemical sensors are designed and tested for use in inert gas backgrounds, from below 1 part-per-million oxygen up to percent-level concentrations. Nitrogen and argon do not interfere with the electrochemical oxygen measurement.
Most of our process analyzers measure below 1000 parts-per-million but can also cover the 0–1% or 0–25% O₂ range depending on the furnace type and process requirement. Please contact our sales team to discuss suitable options.
Yes. The OMD-625 carries ATEX and IECEx certification, making it suitable for monitoring furnace exhaust streams and other hazardous-area points where flammable carrier gases such as hydrogen or endothermic gas are present.
Sensor life is typically 24 – 60 months under most industrial heat treating conditions, however specific furnace temperatures and duty cycles can affect sensor life. We recommend an annual sensor audit and keeping one spare per analyzer for unplanned replacements. Swap-out is tool-free and takes under a few minutes.
Yes. Several models support Modbus RTU or MODBUS ASCII bi-directional digital protocols, allowing direct integration with furnace control or SCADA systems. Contact us to confirm which models match your site’s requirements.
Reliable oxygen monitoring is not optional in metals and thermal processing — it protects **part quality confirms atmosphere integrity ensures **process consistency and keeps personnel safe. Southland Sensing offers a complete range of instruments for every point in the heat treating process.
Наши инженеры по применению оказывают помощь в выборе датчиков, их монтаже и решении вопросов, связанных с эксплуатацией во взрывоопасных зонах.
Наши инженеры по применению готовы помочь с выбором датчиков, предоставить рекомендации по установке и ответить на любые дополнительные вопросы.