OMD-190 Oxygen Analyzer
Online Oxygen Analyzer, Panel Mount Package, Remote Sensor Housing

Applicazioni:
- Inert Glove Box Systems
- Nitrogen and O2 PSA Generators
- Wave Solder Reflow Ovens
- Helium Recovery Systems
- Oxygen Injection in Fish Farms & Many Others
- Oxygen Measurement from 0.01 PPM to 100% Oโ
- Trace, Percent & Oxygen Purity Measurement Ranges
- Auto-Ranging or Manual-Range Operation
- Precision Electrochemical Oxygen Sensor Technology
- Intuitive, User-Friendly Interface
- Two Adjustable Alarm Relay Contacts with Optional Delay
- Designed as a Direct-Fit Replacement for Many Competitive Analyzers
Specifiche Tecniche:
- Accuracy: +/- 1% Full Scale Range
- Display: LCD with Backlight
- Dimensions (Front): 7.00โW x 3.75โH x 2.00โ D
- Panel Cutout Dimensions: 6.00โW x 2.85โH
- Enclosure: Anodized Aluminum
- Classificazione: Uso generale
- Temperature Rating: 0 - 50 deg C
- Temperature Compensation: Integral
- Allarmi: 2 regolabili con modalitร ritardo
- Power: 10 - 28 VDC or 100 - 240 VAC
- Output (Analog): 4 - 20mA (Isolated)
- Communication: Bi-Directional MODBUS RS485 ASCII
- Intervallo: 1 - 5 V CC (opzionale 4 - 20 mA)
- Response time: T90 in 7 Seconds
- Sensor: Configurable
- Sensor Type: Precision Electrochemical
- Calibration: Periodically
- Temperature Compensation: Integral
- Flow Sensitivity: 0.5 - 5 SCFH
- Pressione: 0,1 - 50 PSIG
- Warranty: 12 Months Sensor -- 12 Months Electronics
Direct Fit Drop in Replacement:
The OMD-190 is designed as a panel-mount replacement for many competitive oxygen analyzers, including:
- Teledyne 3190
- Teledyne 3290
- AII GPR-1900
- AII GPR-2900
The OMD-190 utilizes an industry-standard panel cutout, allowing many existing installations to be upgraded with minimal panel modification.
OMD-190 Oxygen Analyzer | Product Specifications
Oxygen Analyzer:
The OMD-190 Oxygen Analyzer combines a compact panel-mount design with Southland Sensingโs precision electrochemical oxygen sensor technology. Designed for both new installations and replacement of existing panel-mount analyzers, the OMD-190 provides reliable and cost-effective trace, percent, and oxygen purity measurement with an intuitive, easy-to-use interface.
Trace oxygen measurement ranges include 0โ10 PPM, 0โ100 PPM, 0โ1,000 PPM, 0โ10,000 PPM, and 0โ25% Oโ. Percent and purity measurement ranges include 0โ1%, 0โ5%, 0โ10%, 0โ25%, and 0โ100% Oโ.
The analyzer can be configured by the user for trace PPM, percent, or oxygen purity measurement by selecting the appropriate oxygen sensor through the built-in menu. This allows the same analyzer platform to support a wide range of oxygen measurement applications.
The analog output can be manually assigned to a selected measurement range through the analyzer menu. Alternatively, the auto-range function can be used in conjunction with the Range ID output to communicate the active measurement range to a PLC, DCS, or other process control system.
Process gas connections are available with compression tube fittings or a KF-40 sensor housing for direct installation into compatible process equipment.
Requisiti di Alimentazione:
Input Power: 100โ240 VAC, 50/60 Hz or 10โ28 VDC
Current Draw: 50 mA nominal (DC operation)
Oxygen Sensor Technology:
The oxygen sensors used in the OMD-190 are based on proven galvanic electrochemical fuel cell technology. All oxygen sensors are manufactured in-house by Southland Sensing Ltd. under a controlled quality program to provide consistent performance, accuracy, and long-term stability.
Multiple sensor chemistries are available to accommodate different process gas compositions. Standard sensors are designed for applications containing background gases such as hydrogen, helium, and hydrocarbons. Acid-resistant sensors are available for applications containing carbon dioxide and other acid gas backgrounds, including many natural gas streams.
Southland Sensing oxygen sensors are completely self-contained and require minimal routine maintenance, with no electrodes to clean or electrolyte to replenish.
Southland Sensingโs precision electrochemical oxygen sensor technology provides reliable oxygen measurement while maintaining long sensor life across a wide range of industrial applications.
Oxygen Sensors:
The OMD-190 is available with multiple oxygen sensor configurations to accommodate trace, percent, and oxygen purity measurement across a variety of process gas compositions.
TO2-1X PPM Oxygen Sensor: Trace Oxygen Analysis โ Standard Applications
TO2-2X PPM Oxygen Sensor: Trace Oxygen Analysis โ Acid Gas Applications
PO2-160 Percent Oxygen Sensor: Percent Oxygen Analysis โ Standard Applications
PO2-24 Percent Oxygen Sensor: Percent Oxygen Analysis โ Acid Gas Applications
PO2-1120 Purity Oxygen Sensor: Oxygen Purity Analysis
TO2-19 Hybrid Oxygen Sensor: Trace or Percent Oxygen Analysis
Oxygen sensors should be periodically calibrated to maintain measurement accuracy. Southland Sensing recommends calibration approximately every 2โ3 months, or at an interval appropriate for the specific application and operating conditions.
The sensors provide excellent linearity and can be conveniently calibrated using ambient air when appropriate. For applications requiring greater calibration accuracy or traceability, a certified span gas can be used.