OMD-190 Oxygen Analyzer
Online Oxygen Analyzer, Panel Mount Package, Remote Sensor Housing

用途
- Inert Glove Box Systems
- Nitrogen and O2 PSA Generators
- Wave Solder Reflow Ovens
- Helium Recovery Systems
- Oxygen Injection in Fish Farms & Many Others
- Precision Electrochemical Sensor Technology
- Intuitive User-Friendly Interface
- Trace, Percent, or Purity Analysis Ranges
- Auto-Ranging or Manual Range Mode
- Two Adjustable Alarm Contacts w/ delay mode
- Panel Mount Design, Direct Fit Replacement
- Measure Oxygen from 0.01ppm to 100%
技術仕様
- Accuracy: +/- 1% Full Scale Range
- Display: LCD with Backlight
- Dimensions (Front): 7.00”W x 3.75”H x 2.00” D
- Panel Cutout Dimensions: 6.00”W x 2.85”H
- Enclosure: Anodized Aluminum
- 分類:汎用
- Temperature Rating: 0 - 50 deg C
- Temperature Compensation: Integral
- アラーム:2系統(調整可能、遅延モード付き)
- Power: 10 - 28 VDC or 100 - 240 VAC
- Output (Analog): 4 - 20mA (Isolated)
- 通信双方向MODBUS RS485 ASCII
- レンジID:1~5 VDC(オプション:4~20 mA)
- Response time: T90 in 7 Seconds
- Sensor: Configurable
- Sensor Type: Precision Electrochemical
- Calibration: Periodically
- Temperature Compensation: Integral
- Flow Sensitivity: 0.5 - 5 SCFH
- 圧力:0.1~50 PSIG
- Warranty: 12 Months Sensor -- 12 Months Electronics
Direct Fit Drop in Replacement:
競合分析計と置き換えるように設計されています:
Teledyne: 3190, 3290
AII / PST: GPR-1900, GPR-2900
OMD-190 Oxygen Analyzer | Product Specifications
Oxygen Analyzer:
The model OMD-190 oxygen analyzer combines a rugged in-line design with SSO2’s precision oxygen sensors. The result is a highly reliable and cost effective compact design with easy-to-use user interface.
Trace ranges include 0 – 10 ppm, 0 – 100 ppm, 0 – 1000ppm, 0-10000ppm and 0 25%. Percent ranges include 0 – 1%, 0 – 5%, 0 – 10%, 0 – 25%, and 0 – 100%. The analyzer can be configured for trace (parts per-million), percent, and purity applications by the user by selecting which sensor is in use in the built-in menu.
The analog output can be manual range selected through the on board menu or the user can take advantage of the auto-range feature using the RANGE ID output allowing easy interface with a PLC, DCS or other control system.
Gas connections are made with compression tube fittings or a direct fit KF-40 Housing.
電源要件
Input Power: 10 – 28 V DC
Input Power: 100 – 240 V AC
Current Draw: 50 mA
Oxygen Sensor Technology:
The oxygen sensors used in the OMD-190 are based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program.
The standard cells are unaffected by other background gases such as H2, He or Hydrocarbons. The acidic cells work well when acid gases such as CO2 or Natural Gas are present.
センサーは自己完結型であり、電極の洗浄や電解液の追加といったメンテナンスは最低限で済む。.
The SSO2 precision oxygen sensors offer excellent performance, accuracy andstability while maximizing the expected life.
Oxygen Sensors:
TO2-1x PPM Oxygen Sensor: Trace Analysis, Standard
TO2-2x PPM Oxygen Sensor: Trace Analysis, Acidic
PO2-160 Percent Oxygen Sensor: Percent Analysis, Standard
PO2-24 Percent Oxygen Sensor: Percent Analysis, Acidic
PO2-1120 Purity Oxygen Sensor: Purity Analysis
TO2-19 Hybrid Oxygen Sensor: Percent or Trace Analysis
Oxygen sensors should be periodically calibrated. Factory recommendation is every 2 – 3 months or as the application dictates. Sensors offer excellent linearity with an air calibration, or calibrate to a certified span gas to maximize accuracy.