OMD-625 Oxygen Analyzer
Hazardous Area Online Process Oxygen Analyzer w/Sample System
Certificazione ATEX e IECEx per aree pericolose

Configurazioni Opzionali:
- Componenti aggiuntivi del sistema di campionamento
- RS485 Modbus RTU bidirezionale
- Involucro per condizioni climatiche estreme
- Intervalli di temperatura estesi
Applicazioni:
- Estrazione di Gas Naturale e Gasdotti
- Trattamento del Gas Naturale
- Acid (CO2) Gas Streams
- Inert, Hydrocarbon, Hydrogen Processing
- E Molte Altre Applicazioni Industriali
- ATEX / IECEx Certified for Zone 1, Group IIB + Hโ Applications
- Oxygen Measurement from 0.01 PPM to 25% Oโ
- User-Configurable Full-Scale Measurement Range
- Tecnologia di sensore elettrochimico di ossigeno di precisione
- Grande display retroilluminato con menu intuitivo
- Due contatti relรจ di allarme completamente configurabili
- Comunicazione MODBUS RS485 RTU opzionale
- Field Calibration of Analog Output
- Analog Output Simulation: 4, 8, 12, 16 & 20 mA
Specifiche Tecniche:
- Precisione: < ยฑ1% del fondo scala
- Allarmi: 2 Contatti Relรจ Configurabili
- Analyzer Range: 0 - 10/100/1000/10000ppm/25%
- Optional Range 1: 0 - 1%,/5%/10%/25%/100%
- Classificazione area: Zona 1 IIB + Hโ
- Dimensioni: 12" ร 12" ร 5,25"
- Flow: 0.5 - 5.0 SCFH
- Connessioni gas: tubo a compressione da 1/4 di pollice
- Uscita: Isolata 4โ20 mA oppure 1โ5 VDC
- Power: 12 - 24 VDC --- 100 - 240 VAC
- Pressione: ingresso 0,1โ50 PSIG, sfiato in atmosfera
- Tempo di risposta: T90 in 10 secondi
- Sensor: Precision Fuel Cell
- Temperatura: 0โ50 ยฐC
- Garanzia sensore: 12 mesi
- Garanzia elettronica: 12 mesi
- Peso: 21 lb
OMD-625 Oxygen Analyzer | Product Specifications
Oxygen Analyzer:
The OMD-625 Oxygen Analyzer combines a rugged hazardous-area design with Southland Sensingโs precision electrochemical oxygen sensor technology. The result is a reliable, cost-effective analyzer designed for continuous trace and percent oxygen measurement in natural gas, hydrogen, biogas, petrochemical, and other demanding industrial applications.
The OMD-625 is certified for installation in Zone 1, Group IIB + Hโ hazardous-area environments.
Both the power input and analog output are electrically isolated, helping prevent ground loops and electrical interference when the analyzer is integrated with plant control and monitoring systems.
Standard trace oxygen measurement ranges include:
0โ10 PPM Oโ
0โ100 PPM Oโ
0โ1,000 PPM Oโ
0โ10,000 PPM Oโ
0โ25% Oโ
Optional percent oxygen measurement ranges include:
0โ1% Oโ
0โ5% Oโ
0โ10% Oโ
0โ25% Oโ
0โ100% Oโ
In addition to the standard measurement ranges, the OMD-625 allows the user to configure a custom full-scale range to match a specific process requirement. For example, a custom range of 0โ94.0 PPM Oโ can be configured when a standard range does not provide the desired measurement span.
Requisiti di Alimentazione:
Input Power: 100โ240 VAC, 50/60 Hz or 12โ24 VDC
Current Draw: 50 mA nominal (DC operation)
Oxygen Sensor Technology:
The oxygen sensor used in the OMD-625 is based on proven galvanic electrochemical fuel cell technology. All oxygen sensors are manufactured in-house by Southland Sensing Ltd. under a controlled quality program to provide consistent performance, accuracy, and long-term stability.
Multiple sensor chemistries are available to accommodate different process gas compositions. Standard sensors are designed for applications containing background gases such as hydrogen, helium, and hydrocarbons. Acid-resistant sensors are available for applications containing carbon dioxide and other acid gas backgrounds, including many natural gas streams.
For sour gas applications, HโS-resistant oxygen sensors are available for process streams containing up to 500 PPM HโS.
Southland Sensing oxygen sensors are completely self-contained and require minimal routine maintenance, with no electrodes to clean or electrolyte to replenish.
Southland Sensingโs precision electrochemical oxygen sensor technology provides reliable oxygen measurement while maintaining long sensor life across a wide range of industrial applications.
Sensori di ossigeno:
The OMD-625 is available with multiple oxygen sensor configurations to accommodate trace and percent oxygen measurement across a variety of process gas compositions.
TO2-133 PPM Oxygen Sensor: Trace Oxygen Analysis โ Standard Applications
TO2-233 PPM Oxygen Sensor: Trace Oxygen Analysis โ Acid Gas Applications
TO2-238 PPM Oxygen Sensor: Trace Oxygen Analysis โ Sour Gas Applications, <500 PPM HโS
PO2-160 Percent Oxygen Sensor: Percent Oxygen Analysis โ Standard Applications
PO2-24 Percent Oxygen Sensor: Percent Oxygen Analysis โ Acid Gas Applications
Oxygen sensors should be periodically calibrated to maintain measurement accuracy. Southland Sensing recommends calibration approximately every 2โ3 months, or at an interval appropriate for the specific application and operating conditions.
The sensors provide excellent linearity and can be conveniently calibrated using ambient air when appropriate. For applications requiring greater calibration accuracy or traceability, a certified span gas can be used.