H2S-625 H2S Analyzer
ATEX and IECEx Certified for Hazardous Areas

Configuraciones opcionales
- Sample System Add-On Components
- Bi-Directional RS485 Modbus RTU
- Protección para clima extremo
- Extended Temperature Ranges
Aplicaciones
- Extracción y gasoductos de gas natural
- Procesamiento de gas natural
- Monitoreo de gas de vertedero
- Biogás antes y después del depurador de H₂S
- Y muchas otras aplicaciones industriales
- ATEX / IECEx Certified for Hazardous-Area Applications
- Designed for Natural Gas, Biogas & Industrial H₂S Applications
- Rangos de medición de 0–10 PPM a 0–10.000 PPM H₂S
- Tecnología de sensor electroquímico H₂S de precisión
- Large Backlit Display with Intuitive Menu Interface
- Two Fully Configurable Alarm Relay Contacts
- Optional MODBUS RS485 RTU Communications
Especificaciones
- Precisión: < ±1 % de escala completa
- Alarmas: 2 contactos de relé configurables
- Analyzer Range: Multiple up to 0 - 10000 ppm
- Area Classification: Zone 1 IIB + H2
- Dimensiones: 12" × 12" × 5.25"
- Flow: 0.50 - 5.0 SCFH
- Gas Connections: 1/4” Compression Tube
- Salida: Aislada 4–20 mA o 1–5 VDC
- Alimentación: 12–24 V CC, 100–240 V CA
- Presión: entrada 0,1–50 PSIG; venteo a atmósfera
- Tiempo de respuesta: T90 en 45 segundos
- Sistema de ejemplo: Opcional
- Sensor: celda electroquímica de precisión
- Temperatura: 0–50 °C
- Garantía del sensor: 12 meses
- Garantía de electrónica: 12 meses
- Peso: 21 lb
Sensibilidad cruzada
- Respuesta del sensor por cada 100 ppm de gas presente:
- Metilmercaptano: 40 ppm
- Monóxido de carbono: 4 ppm
- Hidrógeno: 1 ppm
- Dióxido de azufre: 18 ppm
H2S-625 H2S Analyzer | Product Specifications
Analizador H₂S:
The H2S-625 Hydrogen Sulfide Analyzer combines a rugged hazardous-area design with Southland Sensing’s precision electrochemical H₂S sensor technology. Designed for continuous monitoring in natural gas, biogas, and other demanding industrial applications, the analyzer provides reliable H₂S measurement in a compact, easy-to-operate configuration.
The H2S-625 is certified for installation in Zone 1, Group IIB + H₂ hazardous-area environments, making it suitable for applications where third-party certified instrumentation is required.
Both the power input and analog output are electrically isolated, helping prevent ground loops and other electrical interference that can affect signal stability when the analyzer is integrated with plant control and monitoring systems.
Process gas connections are provided through 1/4″ compression tube fittings. The integral sample system includes a Sample/Span selection valve, flow control, and flow indication for straightforward operation, calibration, and maintenance.
Optional bi-directional MODBUS RS485 RTU communications are available for integration with plant control, SCADA, and data acquisition systems.
Tecnología de sensor H₂S:
The H₂S sensor used in the H2S-625 is based on proven electrochemical fuel cell technology and is designed for reliable hydrogen sulfide measurement across a wide range of industrial applications. Southland Sensing H₂S sensors are manufactured under a controlled quality program to provide consistent performance, accuracy, and long-term stability.
El sensor autónomo requiere un mantenimiento rutinario mínimo, sin limpiar electrodos ni reponer electrolito.
La tecnología de sensores electroquímicos H₂S de precisión de Southland Sensing está diseñada para proporcionar mediciones fiables, maximizar la vida útil del sensor y minimizar el mantenimiento continuo.
Requisitos de alimentación
Input Power: 100–240 VAC, 50/60 Hz or 12–24 VDC
DC Current Draw: 50 mA nominal (DC operation)
Sensores de oxígeno:
H2S-1x PPM H2S Sensor: 0 – 200 Max PPM Range
H2S-2x PPM H2S Sensor: 0 – 2000 Max PPM Range
H2S-3x PPM H2S Sensor: 0 – 10000 MAX PPM Range
Los sensores H₂S deben calibrarse periódicamente. El fabricante recomienda cada 1–3 meses o según la aplicación. Los sensores presentan excelente linealidad cuando se calibran con gas patrón certificado.