H2S-625 H2S Analyzer
ATEX and IECEx Certified for Hazardous Areas

Configurações Opcionais
- Sample System Add-On Components
- Bi-Directional RS485 Modbus RTU
- Proteção para clima extremo
- Extended Temperature Ranges
Aplicações
- Extração de Gás Natural e Gasodutos
- Processamento de Gás Natural
- Monitoramento de Gás de Aterro
- Biogás antes e depois do depurador H₂S
- E Muitas Outras Aplicações Industriais
- ATEX / IECEx Certified for Hazardous-Area Applications
- Designed for Natural Gas, Biogas & Industrial H₂S Applications
- Gamas de medição de 0–10 PPM a 0–10 000 PPM H₂S
- Tecnologia de sensor eletroquímico H₂S de precisão
- Large Backlit Display with Intuitive Menu Interface
- Two Fully Configurable Alarm Relay Contacts
- Optional MODBUS RS485 RTU Communications
Especificações Técnicas:
- Precisão: < ±1% da escala total
- Alarmes: 2 Contatos de Relé Configuráveis
- Analyzer Range: Multiple up to 0 - 10000 ppm
- Area Classification: Zone 1 IIB + H2
- Dimensões: 12" × 12" × 5,25"
- Flow: 0.50 - 5.0 SCFH
- Gas Connections: 1/4” Compression Tube
- Saída: Isolada 4–20 mA ou 1–5 VCC
- Alimentação: 12–24 V CC, 100–240 V CA
- Pressão: entrada 0,1–50 PSIG; ventilação para a atmosfera
- Tempo de resposta: T90 em 45 segundos
- Sistema de Amostragem: Opcional
- Sensor: célula eletroquímica de precisão
- Temperatura: 0–50 °C
- Garantia do sensor: 12 meses
- Garantia da eletrónica: 12 meses
- Peso: 21 lb
Sensibilidade cruzada
- Resposta do sensor por 100 ppm de gás presente:
- Metilmercaptano: 40 ppm
- Monóxido de carbono: 4 ppm
- Hidrogénio: 1 ppm
- Dióxido de enxofre: 18 ppm
H2S-625 H2S Analyzer | Product Specifications
Analisador H₂S:
The H2S-625 Hydrogen Sulfide Analyzer combines a rugged hazardous-area design with Southland Sensing’s precision electrochemical H₂S sensor technology. Designed for continuous monitoring in natural gas, biogas, and other demanding industrial applications, the analyzer provides reliable H₂S measurement in a compact, easy-to-operate configuration.
The H2S-625 is certified for installation in Zone 1, Group IIB + H₂ hazardous-area environments, making it suitable for applications where third-party certified instrumentation is required.
Both the power input and analog output are electrically isolated, helping prevent ground loops and other electrical interference that can affect signal stability when the analyzer is integrated with plant control and monitoring systems.
Process gas connections are provided through 1/4″ compression tube fittings. The integral sample system includes a Sample/Span selection valve, flow control, and flow indication for straightforward operation, calibration, and maintenance.
Optional bi-directional MODBUS RS485 RTU communications are available for integration with plant control, SCADA, and data acquisition systems.
Tecnologia do sensor H₂S:
The H₂S sensor used in the H2S-625 is based on proven electrochemical fuel cell technology and is designed for reliable hydrogen sulfide measurement across a wide range of industrial applications. Southland Sensing H₂S sensors are manufactured under a controlled quality program to provide consistent performance, accuracy, and long-term stability.
O sensor autónomo requer manutenção mínima, sem necessidade de limpar elétrodos ou repor eletrólito.
A tecnologia de sensores eletroquímicos H₂S de precisão Southland Sensing foi concebida para medições fiáveis, vida útil maximizada e manutenção contínua reduzida.
Requisitos de Alimentação
Input Power: 100–240 VAC, 50/60 Hz or 12–24 VDC
DC Current Draw: 50 mA nominal (DC operation)
Sensores de oxigénio:
H2S-1x PPM H2S Sensor: 0 – 200 Max PPM Range
H2S-2x PPM H2S Sensor: 0 – 2000 Max PPM Range
H2S-3x PPM H2S Sensor: 0 – 10000 MAX PPM Range
Os sensores H₂S devem ser calibrados periodicamente. O fabricante recomenda intervalos de 1–3 meses ou conforme a aplicação. A calibração com gás padrão certificado proporciona excelente linearidade.