CO2-525X Carbon Dioxide Analyzer
Online Carbon Dioxide Analyzer, IP66 / NEMA 4X Wall Mount Enclosure
Applications:
- Natural Gas Extraction & Processing Pipelines
- Chemical Plants
- Landfill Gas Monitoring
- Biogas before and after the CO2 Scrubber
- And Many Other Industrial Applications
- Precision NDIR CO2 Sensor
- F.S. Ranges of 0 -5000 ppm up to 0 - 100 %
- Large Easy-to-Read Display
- Intuitive User Friendly Menu Interface
- Compact Indoor or Outdoor Enclosure
- Cost Effective and Low Maintenance
- Integral USB Data Logging
Specifications:
- Accuracy: +/- 1% Full Scale Range*
- Calibration: Periodically
- Alarms: 2 Adjustable w/ delay mode
- Range ID: 1 - 5 VDC (Optional 4 -20mA)
- Communication: Bi-Directional MODBUS RS485 ASCII
- Data Logging: Removable USB Stick
- Power: 100 - 240 VAC or 10 - 28 VDC
- Classification: General Purpose
- Display: LCD with Backlight
- Dimensions: 9.5 x 6.5 x 3.8 Inches
- Enclosure: Anodized Aluminum
- Weight: 4.4 lbs
- Pressure: 0.1 - 50 PSIG
- Flow Rate: 0.5 - 5 SCFH
- Temperature: 0 to 50ยฐ C
- Temperature Compensation:
- Sensor: Precision NDIR Cell
- Response Time: T90 in 30 Seconds
- Gas Connections: Configurable
- Sample System: Optional
- Sensor Warranty: 12 months
- Analyzer Warranty: 12 months
The CO2-525X offers the unique ability to log data in real time via a removable USB drive. Data is logged in an Excel compatible .csv file by date with an interval between 1 and 120 minutes.
Logging at intervals of 1 minute you can store up to ap proximately 50 years worth of data before filling up an 8GB USB flash drive.
CO2-525X Carbon Dioxide Analyzer | Product Specifications
CO2 Analyzer:
The model CO2-525X Carbon Dioxide analyzer combines a rugged design with SSO2โs precision CO2 sensors. The result is a highly reliable and cost effective compact design with an easy-to-use user interface.
The output can be range selected through the on board menu allowing easy interface with a PLC, DCS or other control system.
Gas connections are made with compression tube fittings (1/8โ, 1/4โ or 6mm).
CO2 Sensor Technology:
The Carbon Dioxide sensor used in the CO2-525X is based on the NDIR easurement cell principal. All CO2 sensors are manufactured under a strict quality program.
The sensors are self-contained and minimal main tenance is required – no need to clean electrodes or add electrolyte.
The Southland Sensing precision CO2 sensors offer excellent performance, accuracy and stability while maximizing the expected life.
Integral Alarms Contacts:
2-non latching fully configurable Form C relay contact alarms.
Power Requirements:
Input Power: 10 – 28 V DC or 100 – 240V AC
Current Draw: 100 mA
** Optional power input choices available
CO2 Sensors:
CO2-1x Sensor 0 โ 1000ppm, 2000ppm, 3000ppm, 4000ppm & 5000ppm
CO2-2x Sensor 0 โ 1%, 2%, 3%, 4% & 5%
CO2-3x Sensor 0 โ 5%,10% 25%, 50% & 100%
CO2-3x Sensor 0 โ 100%, 50 โ 100%, 70 โ 100%, 80 โ 100% & 90 โ 100%
CO2 sensors should be periodically calibrated. Sensors offer excellent linearity when calibrated to a certified span gas.