EMD-482 Oxygen Transmitter
Configurable OEM Oxygen Transmitter, 2-wire loop

Anwendungen:
- • Inert Glove Box Systems
- • Nitrogen and O2 PSA Generators
- • Laboratories & Universities
- • Beverage Grade CO2 Monitoring
- • Air Separation Plants Many Others
- Well Suited for OEM Installations
- Precision Fuel Cell Oxygen Sensor Technology
- Spuren- oder Prozentkonfiguration
- Measure Oxygen from 0.1ppm to 100%
- Updated Microprocessor Based Design
- Cost Effective, Compact & Low Maintenance
- Seamlessly integrates with PLC & DCS Systems
Configurations:
User Selectable Ranges (Pre-Configured):
0 – 10ppm/100/1000ppm/1%/5%/10%/25%/100%
Digital Push Buttons to Perform Local Span Cal
Sensor Housings: H6 KF-40 or H3 Flow Through
Optional Display without Backlight
Many additional customized options available
Technische Daten:
- Accuracy: < 1% Full Scale Range*
- Calibration: 2 - 3 months or as needed
- Klassifizierung: Allgemeiner Verwendungszweck
- Dimensions (PCB): 3.25 x 2.00 inch
- Display: Optional
- Temperature: 0 - 50 deg C
- Temperature Compensation: Integral
- Output: 4 - 20mA
- Sensor Housing: Optional, H6 or H3
- Flow Sensitivity: 0.5 - 5.0 SCFH
- Sensor Type: Precision Fuel Cell
- Warranty: 12 Months Sensor
- Warranty: 12 Months Electronics
EMD-482 Oxygen Transmitter | Product Specifications
Oxygen Transmitter:
The model EMD-482 oxygen transmitter combines
a rugged electronic design with SSO2’s precision
oxygen sensors. The result is a highly reliable and
cost effective compact design with an easy-to-use
user interface.
The transmitter comes with a variety of options,
which makes it configurable for a large array of
applications. These options include custom ranges
from 0 – 10ppm through 0 – 100%, a local display,
sensor housings for flow through applications and
ambient monitoring, as well as a variety of oxygen
sensors. See the below ordering guide for complete
options.
This unit is configured as a 2-wire loop powered
device and is idea for integration with a PLC or DCS
system. Output is non-isolated.
Stromversorgung
Input Power: 12 – 24 V DC
Current Draw: 40 mA (max)
Oxygen Sensor Technology:
The oxygen sensor used in the EMD-482 is based on the
galvanic electrochemical fuel cell principal. All oxygen sensors
are manufactured in house by Southland Sensing Ltd. under a
strict quality program.
The standard cells are unaffected by other background gases
such as H2, He or Hydrocarbons. The acidic cells work well
when acid gases such as CO2 or Natural Gas are present.
The sensors are self-contained and minimal maintenance is
required – no need to clean electrodes or add electrolyte.
The SSO2 precision oxygen sensors offer excellent performance, accuracy and stability while maximizing the expected
life.
Oxygen Sensors:
TO2-1x PPM Oxygen Sensor: Trace Analysis, Standard
TO2-2x PPM Oxygen Sensor: Trace Analysis, Acidic
PO2-160 Percent Oxygen Sensor: Percent Analysis, Standard
PO2-24 Percent Oxygen Sensor: Percent Analysis, Acidic
Oxygen sensors should be periodically calibrated. Factory
recommendation is every 2 – 3 months or as the application
dictates. Sensors offer excellent linearity with an air calibration, or calibrate to a certified span gas to maximize accuracy