H2S-780 H2S Analyzer

Technische Daten:
- Accuracy: < +/- 1% of Full Scale Range
- Analysis Range: Multiple up to 10000 PPM
- Battery Indicator: Integrated into Large Display
- Calibration: Periodically
- Data Logging: Removable USB Flash Drive
- Dimensions: 10.9 x 10.0 x 4.9 inch
- Display: Large with Backlight
- Enclosure: Brushed Stainless Steel
- Flow Sensitivity: 0.25 - 5 SCFH
- Gas Connections: 1/8” Compression Tube
- Output (Analog): 0 - 1V DC
- Power: Rechargeable Battery -- 100 - 240 VAC AC Adapter
- Pressure: Inlet, 0 - 50 PSIG
- Response Time: T90 in 45 Seconds
- Probennahmesystem: Durchflussregelung, Durchflussanzeige
- Sensor: Precision Electrochemical
- Sensor Life: 12 - 36 months
- Temperature: 0 - 50 deg C
- Temperature Compensation: Integral
- Warranty: 12 months
- Weight: 11.25 lbs
Cross Sensitivity
- Sensor response per 100 ppm of gas present:
- Methyl Mercaptan: 40 ppm
- Carbon Monoxide: 4 ppm
- Hydrogen: 1 ppm
- Sulfur Dioxide: 18 ppm
- Designed for the Natural Gas Industry
- Large Backlit Display w/ User Friendly Menu
- Data Log via Removable USB Flash Drive
- Integral Flow Control Valve & Flow Indicator
- Continuous Analysis during Charging
- Electrochemical Sensor Technology
The H2S-780 Hydrogen Sulfide Analyzer combines a rugged portable design with SSO2’s precision H2S sensors. The result is a highly reliable and cost effective design with an easy-to-use interface.
The analyzer comes a removable USB flash drive for data logging via .CSV (Excel) file format. With an 8GB USB Flash Drive, you can data log at 1 minute intervals for about 50 years before running out of storage. The low full scale range and flexibility to easily access data makes this analyzer unmatched in the market.
Das Display des Analysators ist für den Einsatz bei direkter Sonneneinstrahlung ausgelegt. Es ist kein Sonnenschutz oder Ähnliches erforderlich, um den Bildschirm ablesen zu können.
Two H2S Sensors are available for the H2S-780. The H2S-1x is preloaded for 4 ranges: 0 – 10ppm, 0 – 50 ppm, 0 – 100 ppm, and 0 – 200 ppm. The H2S-2x is preloaded for: 0 – 100 ppm, 0 – 500 ppm, 0 – 1000 ppm, and 0 – 2000 ppm. The H2S-2x is pre-loaded for 0 – 1000 ppm, 0 – 2000 ppm, 0 – 5000 ppm, and 0 – 10000 ppm.
Die Sensoren sind vollständig gekapselt und nahezu wartungsfrei – eine Reinigung der Elektroden oder das Nachfüllen von Elektrolyt ist nicht erforderlich.
Anwendungen:
- Erdgasförderung und Pipelines
- Erdgasverarbeitung
- Deponiegasüberwachung
- Biogas before and after the H2S Scrubber
- Und viele weitere industrielle Anwendungen
Sensor Options:
- H2S-1x 0 - 200 ppm H2S Sensor
- H2S-2x 0 - 2000 ppm H2S Sensor
- H2S-3x 0 - 10000 ppm H2S Sensor
Optional Configurations:
- ENC-640 Carrying case with foam insert
- PP-640 Integral sampling pump