OMD-507 Oxygen Analyzer

Online PPM, Percent or Purity Oxygen Analyzer Fully Configurable

Uygulama Alanları:

Optional Electronic Configurations:

 2-wire loop powered Non-Isolated 4 – 20mA
 3-wire, isolated 4-20mA & MODBUS ASCII                                           6-wire Analyzer, Non-Isolated 4 – 20mA, 0 – 10VDC & Modbus     ASCII

Teknik Özellikler:

OMD-507 Oxygen Analyzer | Product Specifications

Oxygen Analyzer:

The OMD-507 Oxygen Analyzer combines a compact, versatile design with Southland Sensing’s precision electrochemical oxygen sensor technology. Designed for integration into a wide range of industrial equipment and process systems, the OMD-507 provides reliable and cost-effective trace or percent oxygen measurement with an intuitive, easy-to-use interface.

The analyzer is available in multiple electronic configurations to accommodate different installation requirements. Options include a 2-wire loop-powered configuration, a 3-wire configuration with isolated 4–20 mA output, and a 6-wire configuration with bi-directional MODBUS RS485 ASCII communications. An intrinsically safe configuration is also available for applications requiring appropriately rated instrumentation.

The OMD-507 can be configured for either trace parts-per-million (PPM) or percent oxygen measurement using the appropriate Southland Sensing oxygen sensor and measurement ranges.

The large local display operates in auto-range mode, automatically selecting the appropriate measurement range as the oxygen concentration changes. The analog output range can be selected through the onboard menu for straightforward integration with a PLC, DCS, data acquisition system, or other process control equipment.

Process gas connections are available with compression tube fittings or a KF-40 sensor housing for direct installation into compatible process equipment, including gloveboxes and other controlled-atmosphere systems.

Oxygen Sensor Technology:

The oxygen sensors used in the OMD-507 are based on proven galvanic electrochemical fuel cell technology. All oxygen sensors are manufactured in-house by Southland Sensing Ltd. under a controlled quality program to provide consistent performance, accuracy, and long-term stability.

Multiple sensor chemistries are available to accommodate different process gas compositions. Standard sensors are designed for applications containing background gases such as hydrogen, helium, and hydrocarbons. Acid-resistant sensors are available for applications containing carbon dioxide and other acid gas backgrounds, including many natural gas streams.

Southland Sensing oxygen sensors are completely self-contained and require minimal routine maintenance, with no electrodes to clean or electrolyte to replenish.

Southland Sensing’s precision electrochemical oxygen sensor technology provides reliable oxygen measurement while maintaining long sensor life across a wide range of industrial applications.

Güç Gereksinimleri:

Input Power:   12 – 24 V DC
Current Draw: 25 mA nominal

Oxygen Sensors:

The OMD-507 is available with multiple oxygen sensor configurations to accommodate trace, percent, and oxygen purity measurement across a variety of process gas compositions.

TO2-1X PPM Oxygen Sensor: Trace Oxygen Analysis – Standard Applications
TO2-2X PPM Oxygen Sensor: Trace Oxygen Analysis – Acid Gas Applications
PO2-160 Percent Oxygen Sensor: Percent Oxygen Analysis – Standard Applications
PO2-24 Percent Oxygen Sensor: Percent Oxygen Analysis – Acid Gas Applications
TO2-19 Hybrid Oxygen Sensor: Trace or Percent Oxygen Analysis

Oxygen sensors should be periodically calibrated to maintain measurement accuracy. Southland Sensing recommends calibration approximately every 2–3 months, or at an interval appropriate for the specific application and operating conditions.

The sensors provide excellent linearity and can be conveniently calibrated using ambient air when appropriate. For applications requiring greater calibration accuracy or traceability, a certified span gas can be used.