OMD-507 Oxygen Analyzer
Online PPM, Percent or Purity Oxygen Analyzer Fully Configurable

Ứng dụng:
- Inert Glove Box Systems & 3D Printers
- Laboratories & Universities
- Hàn chảy
- Và nhiều ứng dụng công nghiệp khác
- Precision Fuel Cell Oxygen Sensor Technology
- Measure Oxygen from 0.1ppm to 100%
- Giao diện trực quan, thân thiện với người dùng
- Tiết kiệm chi phí và ít bảo trì
Optional Electronic Configurations:
2-wire loop powered Non-Isolated 4 – 20mA
3-wire, isolated 4-20mA & MODBUS ASCII 6-wire Analyzer, Non-Isolated 4 – 20mA, 0 – 10VDC & Modbus ASCII
Thông số kỹ thuật:
- Accuracy: < +/- 1% of Full Scale Range
- Calibration: Periodically
- Analyzer Range: 0-10/100/1000/10000ppm/25% 0 - 1/5/10/25/100%
- Dimensions: 6.3 x 3.5 x 2.5 inch
- Enclosure: Anodized Aluminum
- Weight: 1.75 lbs
- Pression : 0,1 à 50 PSIG
- Flow Rate: 0.5 - 5 SCFH (Flow Through) ** No Flow Required for KF-40
- Nhiệt độ: 0 đến 50°C
- Temperature Compensation: Integral
- Sensor: Configurable
- Sensor Housing: Configurable
- Kết nối khí: Có thể cấu hình
- Bảo hành cảm biến: 12 tháng
- Bảo hành máy phân tích: 12 tháng
OMD-507 Oxygen Analyzer | Product Specifications
Oxygen Analyzer:
The model OMD-507 oxygen analyzer combines a rugged in-line design with SSO2’s precision oxygen sensors. The result is a highly reliable and cost effective compact design with easy-to-use user interface.
The analyzer comes in 4 different packages for maximum installation considerations. These include 2-wire Loop, 3-wire with an isolated 4-20 mA output, 6 wire with RS485 Bi-Directional Modbus ASCII, and an intrinsically safe option.
The analyzer can be configured for 2 ranges, trace (parts-per-million) or percent.
The display of the analyzer with its large font is set to auto-range, this allows the user to read O2 throughout all ranges. The output can be range selected through the on board menu allowing easy interface with a PLC, DCS or other control system.
Gas connections are made with compression tube fittings or a direct fit KF-40 Housing.
Oxygen Sensor Technology:
The oxygen sensor used in the OMD-507 is based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program.
The standard cells are unaffected by other background gases such as H2, He or Hydrocarbons. The acidic cells work well when acid gases such as CO2 or Natural Gas are present.
Các cảm biến hoạt động độc lập và chỉ yêu cầu bảo trì tối thiểu, không cần vệ sinh điện cực hoặc bổ sung chất điện phân.
The SSO2 precision oxygen sensors offer excellent performance, accuracy and stability while maximizing the expected life.
Yêu cầu nguồn điện:
Input Power: 12 – 24 V DC
Current Draw: 25 mA
Oxygen Sensors:
TO2-1x PPM Oxygen Sensor: Trace Analysis, Standard
TO2-2x PPM Oxygen Sensor: Trace Analysis, Acidic
PO2-160 Percent Oxygen Sensor: Percent Analysis, Standard
PO2-24 Percent Oxygen Sensor: Percent Analysis, Acidic PO2-1120 Purity Oxygen Sensor
TO2-19 Hybrid Oxygen Sensor: Percent or Trace Analysis
Oxygen sensors should be periodically calibrated. Factory recommendation is every 2 – 3 months or as the application dictates. Sensors offer excellent linearity with an air calibration, or calibrate to a certified span gas to maximize accuracy.