OMD-150 Oxygen Analyzer
Configurable Online Wall Mount IP66 / NEMA4X Oxygen Analyzer

Uygulama Alanları:
- Welding & 3D Printers
- N2, O2, H2 Inert Gas Generators
- Laboratories & Universities
- Steel & Other Metal Processing
- Reflow Lehimleme
- Ve Daha Birçok Endüstriyel Uygulama
- İzleme veya Yüzde Yapılandırması
- Precision Fuel Cell Oxygen Sensor Technology
- Measure Oxygen from 0.01 ppm to 100%
- Büyük ve Okunması Kolay Ekran
- Sezgisel ve Kullanıcı Dostu Menü Arayüzü
- Compact Flow Through Design
- Ekonomik ve Düşük Bakım Gerektirir
Optional Electronic Configurations:
2-wire loop transmitter / non backlit display
3-wire loop powered with Isolated 4-20mA Output
6-wire Analyzer , 4 – 20mA and 0 – 10VDC Output
Intrinsically Safe for Class 1, Div. 2 Groups B, C, D
“Smart” xmitter with Bi-Directional RS485 MODBUS
Teknik Özellikler:
- Accuracy: < 1% Full Scale Range
- Approval: CE Certified
- Dimensions: 9.5” x 6.5” x 3.8”
- Enclosure: NEMA 4X / IP66
- Temperature Rating: -10 to 50 deg C
- Temperature Compensation: Integral
- Gaz Bağlantıları: Yapılandırılabilir
- Flow Sensitivity: 0.5 - 5.0 SCFH
- Pressure: 0.1- 50 PSIG
- Sensor Type: Precision Fuel Cell
- Warranty: 12 Months Sensor
- Warranty: 12 Months Electronics
OMD-150 Oxygen Analyzer | Product Specifications
Oxygen Analyzer:
The model OMD-150 oxygen analyzer combines a rugged in-line design with SSO2’s precision oxygen sensors. The result is a highly reliable and cost effective compact design with an easy-to-use user interface.
The analyzer comes in a variety of different packages for maximum installation considerations. These include 2-wire, 3-wire with isolated 4 20 mA output, 6-wire, and an intrinsically safe option.
The analyzer can be configured for trace (parts-permillion) or percent analysis.
The display of the analyzer with its large font is set to auto-range, this allows the user to read O2 throughout all ranges. The output can be range selected through the onboard menu allowing easy interface with a PLC, DCS or other control system.
Gaz bağlantıları, sıkıştırmalı tip boru bağlantı elemanları (1/8”, 1/4” veya 6 mm) ile yapılır.
Güç Gereksinimleri:
Input Power: 10 – 28 V DC
Input Power: 100 – 240 V AC
Current Draw: 50 mA
Oxygen Sensor Technology:
The oxygen sensor used in the OMD-150 is based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program.
The standard cells are unaffected by other background gases such as H2, He or Hydrocarbons. The acidic cells work well when acid gases such as CO2 or Natural Gas are present.
Sensörler bağımsız yapıdadır ve minimum bakım gerektirir; elektrot temizliği veya elektrolit eklenmesine ihtiyaç yoktur.
The SSO2 precision oxygen sensors offer excellent performance, accuracy and stability while maximizing the expected life.
Oxygen Sensors:
TO2-1x PPM Oxygen Sensor: Trace Analysis, Standard
TO2-2x PPM Oxygen Sensor: Trace Analysis, Acidic
PO2-160 Percent Oxygen Sensor: Percent Analysis, Standard
PO2-24 Percent Oxygen Sensor: Percent Analysis, Acidic
TO2-19 Hybrid Oxygen Sensor: Percent or Trace Analysis
Oxygen sensors should be periodically calibrated. Factory recommendation is every 2 – 3 months or as the application dictates. Sensors offer excellent linearity with an air calibration, or calibrate to a certified span gas to maximize accuracy.