OMD-775 Oxygen Analyzer
Online Oxygen Purity Analyzer w/ Integral Sample System

Технические характеристики
- Точность: < ±1 % полной шкалы*
- Alarms: (2) Adjustable Relay Contacts (1) Power Fail Relay Contact
- Analysis Range: 0/50/80/90 - 100%
- Калибровка: периодическая
- Communication: Bi-Directional RS232 MODBUS RS485 ASCII
- Dimensions: 19.0 x 5.125 x 7.75 inch
- Дисплей: большой, с подсветкой
- Корпус: шлифованная нержавеющая сталь
- Flow Sensitivity: 0.5 - 5 SCFH
- Газовое соединение: компрессионная трубка 1/8 дюйма
- Output (Analog): 0 - 1V DC, 0 - 10V DC Isolated 4 - 20mA
- Питание: 100–240 В переменного тока
- Давление: вход 0–50 PSIG
- Range ID: 4 - 20 mA analog output 0 - 1 V DC analog output
- Время отклика: T90 за 30 секунд
- Sample System: Flow Control, 4-way sample / Flow Indicator
- Sensor: PO2-1120 Percent O2 Sensor
- Sensor Life: 20 - 25 months @ 100% O2
- Температура: 0–50 °C
- Temperature Compensation: Digital
- Гарантия: 12 месяцев на анализатор и датчик
- Масса: 13,0 фунта
- 0–100% O₂ with 50–100%, 80–100% & 90–100% Suppressed Ranges
- Advanced Digital Temperature Compensation
- Bi-Directional Digital Communications via MODBUS RS485 RTU
- Comprehensive Analog & Digital Outputs
- 19” Rack Mount Configuration
- Прецизионная электрохимическая технология датчика кислорода
The OMD-775 is designed for continuous online measurement of elevated oxygen concentrations from 21–100% O₂. Combining advanced electronics with Southland Sensing’s precision electrochemical oxygen sensor technology, the analyzer provides accurate and reliable oxygen purity measurement in a cost-effective 19″ rack-mount configuration.
The OMD-775 features integral digital temperature and barometric pressure compensation to improve measurement accuracy across changing operating conditions. The standard 0–100% O₂ measurement range provides 0.01% resolution, while user-selectable suppressed ranges of 50–100%, 80–100%, and 90–100% O₂ provide enhanced resolution for high-purity oxygen applications. Automatic ranging across all four measurement ranges is also available.
Analog output options include voltage or current outputs for connection to process control and data acquisition systems. Bi-directional digital communications are provided through MODBUS RS485 RTU.
Two fully adjustable Form C, non-latching alarm relays can be independently configured for high or low oxygen conditions, normally open or normally closed operation, and optional alarm delay. A dedicated Form C, non-latching power-failure alarm relay is also provided as standard.
At the heart of the OMD-775 is Southland Sensing’s galvanic electrochemical oxygen sensor. The sensor is manufactured in-house under a controlled quality program and works in conjunction with the analyzer’s temperature and barometric pressure compensation to provide dependable high-concentration oxygen measurement.
The OMD-775 provides a reliable, cost-effective alternative to traditional paramagnetic oxygen analyzers for applications where continuous high-purity oxygen measurement is required. Its standard 19″ rack-mount configuration, field-selectable measurement ranges, comprehensive outputs, and straightforward user interface make it easy to integrate into new or existing process systems.
Области применения
- Air Liquefaction and Separation
- Gas Purity Certification
- Oxygen Monitoring of Medical Gases
- Ozone Generation PSA, VPSA
- Measurement in Wastewater Treatment Plants