OMD-677 Oxygen Analyzer
Online Trace Oxygen Analyzer w/ Integral Sample System

The OMD-677 is designed to measure trace oxygen in the sub 1 ppm region. The unit combines an advanced set of electronic features with our, industry leading, precision electrochemical oxygen sensor technology. The result is a highly reliable and cost effective design with easy-to-use user interface.
The analyzer comes with a 0 -1 PPM full scale low range with a resolution of 0.001 ppm. The analyzer can also be configured for 0 – 1 ppm, 0 – 10ppm, 0 – 100ppm, 0 – 1000ppm and 0 – 25% in autorange or manual-range mode.
The analyzer offers the user 2 different digital communication options, both of which are bi-directional. This comes in the form of MODBUS RS485 ASCII or RS232.
Alarm functionality comes in the way of 2 fully adjustable form C non-latching relay contacts. These can be configured as NO or NC and can be set as HIGH or LOW with optional delay mode. A power failure alarm is also standard and comes as a form C nonlatching relay contact.
The oxygen sensor used in the OMD-677 is based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program.
The standard cell (TO2-133T) is unaffected by other background gases such as H2, He, or Hydrocarbons. The optional acidic cell (TO2-233T) works well when acid gases such as CO2 or Natural Gas are present.
Les capteurs sont autonomes et nécessitent un entretien minimal. Il n'est pas nécessaire de nettoyer les électrodes ni d'ajouter un électrolyte.
Applications :
- Air Liquefaction and Separation
- Pure, Gaseous Hydrocarbon Stream Monitoring
- Gas Purity Certification
- Process Monitoring of Gaseous Monomers
- Fabrication de semi-conducteurs
- Protective Atmosphere Blanketing of Feedstock
- 0 - 1 PPM Low Range; 0 - 25% High Range
- Resolution of 0.001 Parts-Per-Million Oxygen
- Integral Sample System w/ Bypass Valve
- Bi-Directional Communication Link
- Extensive Electronic Features & Outputs
- Configuration du montage sur panneau
- Electrochemical Sensor Technology
Spécifications :
- Accuracy: < +/- 1% of Full Scale Range
- Alarms: (2) Adjustable Relay Contacts (1) Power Fail Relay Contact
- Analysis Range: 0-1/10/100/1000ppm/25%
- Calibration: Periodically
- Communication: Bi-Directional RS232 -- MODBUS RS485 ASCII
- Dimensions: 10.78 x 7.47 x 7.75 inch
- Display: Large with Backlight
- Enclosure: Brushed Stainless Steel
- Flow Sensitivity: 0.5 - 5 SCFH
- Gas Connections: 1/8” Compression Tube
- Output (Analog): 0 - 1V DC, 0 - 10V DC -- Isolated 4 - 20mA
- Power: 100 - 240 VAC
- Pressure: Inlet, 0 - 50 PSIG
- Range ID: 4 - 20 mA analog output -- 0 - 1 V DC analog output
- Response Time: T90 in 10 Seconds
- Sample System: Flow Control, 4-way sample / Bypass Valve, Flow Indicator
- Sensor: TO2-133T Trace O2 Sensor
- Sensor Life: 20 - 25 months
- Temperature: 0 - 50 deg C
- Temperature Compensation: Digital
- Warranty: 12 months Analyzer & Sensor
- Weight: 12.0 lbs
Direct Fit Field Replacement:
- Designed to replace competitive analyzers:
- Teledyne: 3000TA, 3000TA-XL
- AII: GPR-1600, GPR-1600MS, PI2-MS-1000