H2S-150 H2S Analyzer

Configuraciones opcionales
- Customizeable Measurement Ranges
- Sample Conditioning Systems
- Bi-Directional RS485 Modbus ASCII
- Extreme Weather Packaging
Aplicaciones
- Extracción y gasoductos de gas natural
- Procesamiento de gas natural
- Monitoreo de gas de vertedero
- Biogas before and after the H2S Scrubber
- Y muchas otras aplicaciones industriales
- F.S. Ranges of 0 - 10 ppm up to 0 - 10,000 ppm
- Precision Electrochemical H2S Sensor
- Large Backlight Display w/ Auto-Range
- nterfaz intuitiva y fácil de usar
- Rentable y de bajo mantenimiento
- MODBUS RS485 ASCII (Optional)
Especificaciones
- Accuracy: < +/-1% Full Scale Range
- Area Classification: General Purpose
- Approval: CE Certified
- Dimensions: 9.5” x 6.5” x 3.8”
- Flow: 0.5 - 2.0 SCFH
- Gas Connections: “Multiple Options”
- Output: 4 - 20mA and 0 - 10 V DC
- Salida: Aislada 4–20 mA o 1–5 VDC
- Power: 12 - 24 VDC 100 - 240 VAC
- Pressure 0.1 - 50 PSIG Inlet, vent to atm
- Response Time: T90 in 45 Seconds
- Sistema de ejemplo: Opcional
- Sensor: Precision Electrochemical Cell
- Temperature: 0 to 50 deg C
- Warranty Sensor: 12 Months
- Warranty Electronics: 12 Months
Cross Sensitivity
- Sensor response per 100 ppm of gas present:
- Methyl Mercaptan: 40 ppm
- Carbon Monoxide: 4 ppm
- Hydrogen: 1 ppm
- Sulfur Dioxide: 18 ppm
H2S-150 H2S Analyzer | Product Specifications
H2S Analyzer:
The model H2S-150 Hydrogen Sulfide analyzer combines a rugged design with SSO2’s precision H2S sensors. The result is a highly reliable and cost effective compact design an with easy-to-use interface designed specifically for the Natural Gas Industry.
The H2S analyzer is CE Certified and designed for outdoor installations requiring an IP66 / NEMA4X rated enclosure.
Gas connections are made with Compression tube fittings and available in 1/8”, 1/4” or 6mm. Optional sample systems available and configured based on application needs.
The analyzer comes in 2 different configurations. Standard 6-wire (12 – 24VDC input, 4 – 20mA and 0 – 10VDC Analog Output), or 6-wire with Bi-Directional MODBUS RS-485 ASCII.
H2S Sensor Technology:
The H2S sensor used in the H2S-150 is based on the galvanic electrochemical fuel cell principal. All H2S sensors are manufactured under a strict quality program.
Los sensores son autónomos y requieren un mantenimiento mínimo: no es necesario limpiar los electrodos ni añadir electrolito.
The Southland Sensing precision H2S sensors offer excellent performance, accuracy and stability while maximizing the expected life.
Requisitos de alimentación
Input Power: 12 – 24 V DC
Current Draw: 50 mA
Oxygen Sensors:
H2S-1x PPM H2S Sensor: 0 – 200 MAX PPM Range
H2S-2x PPM H2S Sensor: 0 – 2000 MAX PPM Range
H2S-3x PPM H2S Sensor: 0 – 10000 MAX PPM Range
H2S sensors should be periodically calibrated. Factory recommendation is every 1 – 3 months or as the application dictates. Sensors offer excellent linearity when calibrated to a certified span gas.