OMD-525X Oxygen Analyzer

Online Trace Oxygen Analyzer, IP66 / NEMA 4X Wall Mount Enclosure

적용 분야:

사양:

The OMD-525X offers the unique ability to log data in real time via a removable USB drive. Data is logged in an Excel compatible .csv file by date with an interval between 1 and 120 minutes.

Logging at intervals of 1 minute you can store up to approximately 50 years worth of data before filling up an 8GB USB flash drive.

The analyzer can be configured for trace (parts-per-million), percent, or purity applications by the user by selecting the desired ranges in the built-in menu and using the appropriate sensor.

OMD-525X Oxygen Analyzer | Product Specifications

Oxygen Analyzer:

The model OMD-525X oxygen analyzer combines a rugged in-line design with SSO2’s precision oxygen sensors. The result is a highly reliable and cost effective compact design with an easy-to-use user interface.

The analyzer can be configured for either 10-28 VDC or 100 240 VAC power to fit a variety of applications. It can also be configured for trace, (partsper million) percent, or purity analysis using the on-board menu and correct sensor.

The auto-range feature allows the user to read O2 throughout all relevant ranges on the local display in large font.

The output can be range selected through the onboard menu allowing easy interface with a PLC, DCS or other control system.

가스 연결은 압축 튜브 피팅(1/8인치, 1/4인치 또는 6mm)을 사용하여 이루어집니다.

Optional Alarms:

완전 설정 가능한 2개의 Form C 릴레이 접점 알람 (비래칭 방식)

Oxygen Sensor Technology:

The oxygen sensor used in the OMD-525X is based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program.

The standard cells are unaffected by other background gases such as H2, He or Hydrocarbons. The acidic cells work well when acid gases such as CO2 or Natural Gas are present.

이 센서는 전극을 청소하거나 전해질을 추가할 필요가 없는 독립형 센서로 최소한의 유지보수가 필요합니다.

The SSO2 precision oxygen sensors offer excellent performance, accuracy and stability while maximizing the expected life.

Oxygen Sensors:

TO2-1x PPM Oxygen Sensor: Trace Analysis, Standard
TO2-2x PPM Oxygen Sensor: Trace Analysis, Acidic
PO2-160 Percent Oxygen Sensor: Percent Analysis, Standard
PO2-24 Percent Oxygen Sensor: Percent Analysis, Acidic
PO2-1120 Purity Oxygen Sensor: Percent Analysis, Standard
TO2-19 Hybrid Oxygen Sensor: Percent or Trace Analysis

Oxygen sensors should be periodically calibrated. Factory recommendation is every 2 – 3 months or as the application dictates. Sensors offer excellent linearity with an air calibration, or calibrate to a certified span gas to maximize accuracy.

제품 문서