EMD-485 Oxygen Transmitter
Configurable OEM Oxygen Transmitter, 6-wire

Сфери застосування:
- Inert Glove Box Systems
- Nitrogen and O2 PSA Generators
- Laboratories & Universities
- Beverage Grade CO2 Monitoring
- Air Separation Plants & Many Others
- Well Suited for OEM Installations
- Precision Fuel Cell Oxygen Sensor Technology
- Конфігурація трасування або відсоткова конфігурація
- Measure Oxygen from 0.1ppm to 100%
- 4 - 20mA, 0 - 1V DC, 0 - 10V DC Outputs
- Updated Microprocessor Based Design
- Cost Effective, Compact & Low Maintenance
Configurations:
User Selectable Ranges (Pre-Configured):
0 – 10ppm/100/1000ppm/1%/5%/10%/25%/100%
Digital Push Buttons to Perform Local Span Cal
Sensor Housings: H6 KF-40 or H3 Flow Through
Graphical Display with Backlight
Many additional customized options available
Integral Span Pot to Adjust 4mA Offset
Технічні характеристики:
- Accuracy: < 1% Full Scale Range
- Calibration: 2 - 3 months or as needed
- Класифікація: Загальне призначення
- Dimensions (PCB): 3.25 x 2.00 inch
- Display: Optional
- Temperature: 0 - 50 deg C
- Temperature Compensation: Integral
- Output: 4 - 20mA, 0 - 1VDC, 0 - 10VDC
- Sensor Housing: Optional, H6 or H3
- Flow Sensitivity: 0.5 - 5.0 SCFH
- Sensor Type: Precision Fuel Cell
- Warranty: 12 Months Sensor
- Warranty: 12 Months Electronics
EMD-485 Oxygen Transmitter | Product Specifications
Oxygen Transmitter:
The model EMD-485 oxygen transmitter combines a rugged electronic design with SSO2’s precision oxygen sensors. The result is a highly reliable and cost effective compact design with an easy-to-use user interface.
The transmitter comes with a variety of options, which makes it configurable for a large array of applications. These options include custom ranges from 0 – 10ppm through 0 – 100%, a local display, sensor housings for flow through applications and ambient monitoring, as well as a variety of oxygen sensors. See the below ordering guide for complete options.
Вимоги до живлення:
Input Power: 12 – 24 V DC
Current Draw: 40 mA (max)
Oxygen Sensor Technology:
The oxygen sensor used in the EMD-485 is based on the galvanic electrochemical fuel cell principal. All oxygen sensors are manufactured in house by Southland Sensing Ltd. under a strict quality program.
The standard cells are unaffected by other background gases such as H2, He or Hydrocarbons. The acidic cells work well when acid gases such as CO2 or Natural Gas are present.
Датчики є автономними та потребують мінімального обслуговування — очищення електродів або додавання електроліту не потрібне.
The SSO2 precision oxygen sensors offer excellent performance, accuracy and stability while maximizing the expected life.
Oxygen Sensors:
TO2-1x PPM Oxygen Sensor: Trace Analysis, Standard
TO2-2x PPM Oxygen Sensor: Trace Analysis, Acidic
PO2-160 Percent Oxygen Sensor: Percent Analysis, Standard
PO2-24 Percent Oxygen Sensor: Percent Analysis, Acidic
Oxygen sensors should be periodically calibrated. Factory recommendation is every 2 – 3 months or as the application dictates. Sensors offer excellent linearity with an air calibration, or calibrate to a certified span gas to maximize accuracy.