{"id":1741,"date":"2021-07-30T19:50:30","date_gmt":"2021-07-30T19:50:30","guid":{"rendered":"https:\/\/sso2.com\/?page_id=1741"},"modified":"2025-10-10T17:57:42","modified_gmt":"2025-10-10T17:57:42","slug":"medical-oxygen-sensors","status":"publish","type":"page","link":"https:\/\/sso2.com\/pt\/medical-oxygen-sensors\/","title":{"rendered":"Sensores de oxig\u00e9nio m\u00e9dico"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1741\" class=\"elementor elementor-1741\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-64dc1556 elementor-section-items-stretch elementor-section-height-min-height elementor-section-boxed elementor-section-height-default\" data-id=\"64dc1556\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2ee0a9be\" data-id=\"2ee0a9be\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-4dc28969 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4dc28969\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-19dfec03\" data-id=\"19dfec03\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-78016b1a elementor-widget__width-auto elementor-widget elementor-widget-heading\" data-id=\"78016b1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"https:\/\/sso2.com\/pt\/\">In\u00edcio<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4065b048 elementor-widget__width-initial elementor-view-default elementor-widget elementor-widget-icon\" data-id=\"4065b048\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-wrapper\">\n\t\t\t<div class=\"elementor-icon\">\n\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-slash\" viewbox=\"0 0 640 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M594.53 508.63L6.18 53.9c-6.97-5.42-8.23-15.47-2.81-22.45L23.01 6.18C28.43-.8 38.49-2.06 45.47 3.37L633.82 458.1c6.97 5.42 8.23 15.47 2.81 22.45l-19.64 25.27c-5.42 6.98-15.48 8.23-22.46 2.81z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-678b23b4 elementor-widget__width-auto elementor-widget elementor-widget-heading\" data-id=\"678b23b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-heading-title elementor-size-default\"><a href=\"#\">Sensores de oxig\u00e9nio m\u00e9dico<\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-3824c652 elementor-reverse-tablet elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3824c652\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-3ce93776\" data-id=\"3ce93776\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-44c4f37b elementor-widget elementor-widget-heading\" data-id=\"44c4f37b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Sensores de oxig\u00e9nio m\u00e9dico<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2b6076dc\" data-id=\"2b6076dc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-48b45863 animated-fast elementor-invisible elementor-widget elementor-widget-image\" data-id=\"48b45863\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;fadeInLeft&quot;,&quot;_animation_mobile&quot;:&quot;none&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"2560\" height=\"1707\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?fit=2560%2C1707&amp;ssl=1\" class=\"attachment-full size-full wp-image-2780\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?w=2560&amp;ssl=1 2560w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?resize=300%2C200&amp;ssl=1 300w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?resize=1024%2C683&amp;ssl=1 1024w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?resize=768%2C512&amp;ssl=1 768w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?resize=1536%2C1024&amp;ssl=1 1536w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?resize=2048%2C1365&amp;ssl=1 2048w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?resize=600%2C400&amp;ssl=1 600w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?w=1600&amp;ssl=1 1600w, https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg?w=2400&amp;ssl=1 2400w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t<div class=\"elementor-element elementor-element-e1574f e-flex e-con-boxed e-con e-parent\" data-id=\"e1574f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2f83cdfa elementor-widget elementor-widget-text-editor\" data-id=\"2f83cdfa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><b>Sensores de oxig\u00e9nio m\u00e9dico da Southland Sensing Ltd<\/b><\/h2><p>Apoiado por um excelente servi\u00e7o ao cliente e um design de produto comprovado na ind\u00fastria,<span style=\"font-size: 16px; text-align: var(--text-align); background-color: var( --e-global-color-4903f0f ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); letter-spacing: var( --e-global-typography-text-letter-spacing );\">eading health care providers and OEM manufacturers around the world partner with Southland Sensing Ltd. to improve sensor performance and quality while lowering their annual maintenance costs.<\/span><\/p><p>A nossa equipa de especialistas seleciona e testa cuidadosamente cada produto para cumprir os nossos rigorosos padr\u00f5es de qualidade (Somos certificados ISO9001 e ISO13485). Compreendemos que a qualidade \u00e9 crucial para os nossos clientes e garantimos que cada produto cumpra ou exceda as expectativas.<\/p><p><span style=\"font-size: 16px; text-align: var(--text-align); background-color: var( --e-global-color-4903f0f ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); letter-spacing: var( --e-global-typography-text-letter-spacing );\">Para uma refer\u00eancia cruzada equivalente a sensores concorrentes, consulte os nossos <\/span><a style=\"font-size: 16px; text-align: var(--text-align); background-color: var( --e-global-color-4903f0f ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; letter-spacing: var( --e-global-typography-text-letter-spacing );\" href=\"https:\/\/sso2.com\/pt\/medical-replacement-guide-for-fuel-cell-oxygen-sensors\/\">Guia de Substitui\u00e7\u00e3o<\/a><span style=\"font-size: 16px; text-align: var(--text-align); background-color: var( --e-global-color-4903f0f ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); letter-spacing: var( --e-global-typography-text-letter-spacing );\">.<\/span><\/p><p><span style=\"font-size: 16px; text-align: var(--text-align); background-color: var( --e-global-color-4903f0f ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); letter-spacing: var( --e-global-typography-text-letter-spacing );\">\n<table id=\"tablepress-23\" class=\"tablepress tablepress-id-23\">\n<thead>\n<tr class=\"row-1\">\n\t<td class=\"column-1\"><\/td><th class=\"column-2\">N\u00daMERO DE PE\u00c7A<\/th><th class=\"column-3\">OEM Equipment<\/th><th class=\"column-4\">INFORMA\u00c7\u00c3O ADICIONAL<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-1_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-1_brochure.pdf\">OKS-1<\/a><\/td><td class=\"column-3\">Vyaire \/ Carefusion Avea<br \/>\nVyaire \/ Carefusion Sipap<br \/>\nVentilador GE Ivent<br \/>\nVentiladores Versamed eVent<br \/>\nVentilador S\u00e9rie Siemens 300 \/ 900<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: conector Molex de 3 pinos<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-1_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-1_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-2_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-2_brochure.pdf\">OKS-2<\/a><\/td><td class=\"column-3\">Monitor Mindray A5<br \/>\nTaema (Fran\u00e7a) Alys<br \/>\nTaema (Fran\u00e7a) Clarys<br \/>\nMindray Wato EX-30 \/ EX-20<br \/>\nMindray Wato EX-50 \/ EX-55<br \/>\nMindray Wato EX-60 \/ EX-65<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14mV<br \/>\nVida \u00fatil do sensor:  < 60 months @ 20.9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-2_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Folheto OKS-2<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-3_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-3_brochure.pdf\">OKS-3<\/a><\/td><td class=\"column-3\">Sensidyne &#8211; 1000- E<br \/>\nMindray AS  3000<br \/>\n<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14mV<br \/>\nVida \u00fatil do sensor:  &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: AMP #520257-2<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-3_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-3_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-4_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-4_brochure.pdf\">OKS-4<\/a><\/td><td class=\"column-3\">Contacte a f\u00e1brica para informa\u00e7\u00f5es adicionais<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14mV<br \/>\nVida \u00fatil do sensor:  &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: AMP #520257-2<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-4_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-4_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-5_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-5_brochure.pdf\">OKS-5<\/a><\/td><td class=\"column-3\">GE \/ Datex Ohmeda 7900 Smart Vent Ventilador<br \/>\nGE \/ Datex Ohmeda 7100 Smart Vent Ventilador<br \/>\nGE \/ Datex Ohmeda Aestiva 3000 \/ 5 M\u00e1quina de anestesia<br \/>\nGE \/ Datex Ohmeda Aespire Ventilador<br \/>\nGE \/ Datex Ohmeda ADU sem suporte OEM<br \/>\nGE \/ Datex Ohmeda Avance com suporte OEM<br \/>\nGE \/ Datex Ohmeda Asys com suporte OEM<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: AMP 6P4C Ficha telef\u00f3nica<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-5_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-3_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-6_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-6_brochure.pdf\">OKS-6<\/a><\/td><td class=\"column-3\">Monitor Newport 0M100<br \/>\nMonitor Sechrist 650<br \/>\nAnalisador Teledyne 60T<br \/>\nMonitor Teledyne 191<br \/>\nMonitor Teledyne 200<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 7 \u2013 14\u202fmV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: 4P4C AMP Ficha telef\u00f3nica<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-6_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-6_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-8_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-8_brochure.pdf\">OKS-8<\/a><\/td><td class=\"column-3\">Analytical Industries \u2013 AII-2000A<br \/>\nAnalytical Industries \u2013 AII-2000M<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 3,5 \u2013 5,5\u202fmV<br \/>\nVida \u00fatil do sensor:  &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: 4P4C AMP Ficha telef\u00f3nica<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-8_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-8_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-11_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-11_brochure.pdf\">OKS-11<\/a><\/td><td class=\"column-3\">Ventiladores PB 840<br \/>\nVentiladores PB 760<br \/>\nVentilador GE Ivent<br \/>\nVentiladores Versamed eVent<br \/>\nVentilador S\u00e9rie Siemens 300 \/ 900<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 13 \u2013 16\u202fmV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Conector Molex de 3 pinos<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-11_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-11_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-12_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-12_brochure.pdf\">OKS-12<\/a><\/td><td class=\"column-3\">Monitor Criticare System Poet<br \/>\nHamilton Arabella<br \/>\nVentilador Hamilton Galileo<br \/>\nVentilador Hamilton G5<br \/>\nVentilador Hamilton Raphael<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Conector Molex de 3 pinos<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-12_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-12_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-13_jpg.jpg?w=800&#038;ssl=1\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-13_brochure.pdf\">OKS-13<\/a><\/td><td class=\"column-3\">Incubadora Atom V-2100G<br \/>\nIncubadora Atom V-2100G<br \/>\nIncubadora Dr\u00e4ger C2000<br \/>\nIncubadora Dr\u00e4ger\/Airshield Isolette<br \/>\ncom monitor incorporado<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 13\u202fmV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: conector Molex de 3 pinos<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-13_brochure.pdf\">OKS-13_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-14_jpg.jpg?w=800&#038;ssl=1\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-14_brochure.pdf\">OKS-14<\/a><\/td><td class=\"column-3\">Incubadora Atom 100 Dual Incu I<br \/>\nIncubadora Atom 100 Dual Incu I<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 13\u202fmV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: conector Molex de 3 pinos<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-14_brochure.pdf\">OKS-1_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-15_jpg.jpg?w=800&#038;ssl=1\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-15_brochure.pdf\">OKS-15<\/a><\/td><td class=\"column-3\">Contacte a f\u00e1brica para informa\u00e7\u00f5es adicionais<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 13,5\u202fmV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: conector Molex de 3 pinos<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-15_brochure.pdf\">OKS-1_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-19_jpg.jpg?w=800&#038;ssl=1\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-19_brochure.pdf\">OKS-19<\/a><\/td><td class=\"column-3\">Analisador MED-19<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: AMP #520257-2<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-19_brochure.pdf\">OKS-1_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-21_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-21_brochure.pdf\">OKS-21<\/a><\/td><td class=\"column-3\">Monitores Dixtal Philips<br \/>\nIncubadora MEDIX Natalcare<br \/>\nAnalisador MSA Mini Ox I, II<br \/>\nMonitor MSA Mini Ox III, 3000<br \/>\nPrecision Medical PM5900 &amp; PM5900L<br \/>\nMonitor Puritan Bennet 7820<br \/>\nVentilador Philips Respironics Esprit<br \/>\nVentilador Philips Respironics Esprit<br \/>\nVentilador Stephan Christina<br \/>\nVentilador Taema Ceasar (vers\u00e3o mais recente)<br \/>\nVentilador Taema Eolo<br \/>\nAnalisador Teledyne 60T<br \/>\nMonitor Teledyne 191<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 9 \u2013 14 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-21_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-13_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-23_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-23_brochure.pdf\">OKS-23<\/a><\/td><td class=\"column-3\">Envitec OOM202-1<br \/>\nIT Gambert M-03<br \/>\nPrecision Medical PM5900 &amp; PM5900L<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 13 \u2013 16\u202fmV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-23_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-39_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-39_brochure.pdf\">OKS-39<\/a><\/td><td class=\"column-3\">Spacelabs Blease Anesthesia Machine<br \/>\nM\u00e1quina de Anestesia Spacelabs Sirius<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: 4P4C AMP Ficha telef\u00f3nica<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-39_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250_brochure.pdf\">OKS-250<\/a><\/td><td class=\"column-3\">Analisador Maxtec OM25A<br \/>\nSistema Vapotherm Precision Flow<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Conector el\u00e9trico <br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250b_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250b_brochure.pdf\">OKS-250B<\/a><\/td><td class=\"column-3\">Contacte a f\u00e1brica para informa\u00e7\u00f5es adicionais<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Conector el\u00e9trico<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250b_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250d_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250d_brochure.pdf\">OKS-250D<\/a><\/td><td class=\"column-3\">SLE 2000 (Ventilador vendido apenas internacionalmente)<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250d_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250e_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250e_brochure.pdf\">OKS-250E<\/a><\/td><td class=\"column-3\">Misturador de gases Vyaire \/ Carefusion Bird Sentry<br \/>\nVentilador Newport HT-70<br \/>\nVentilador Newport HT-70<br \/>\nVentilador Newport HT-70<br \/>\nAnalisador Maxtec OM25A<br \/>\nMonitor de Oxig\u00e9nio Maxtec OM-25ME \/ OM-25MEL<br \/>\nMisturador de gases Maxtec MaxBlend<br \/>\nSistema Maxtec Venturi<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250e_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250f_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250f_brochure.pdf\">OKS-250F<\/a><\/td><td class=\"column-3\">Maxtec OMO2+ A<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250f_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250g_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250g_brochure.pdf\">OKS-250G<\/a><\/td><td class=\"column-3\">Ventiladores PB 840<br \/>\nPB 980 &amp; 960 Ventilators<br \/>\nPB 10097559 (Sensor de Oxig\u00e9nio)<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250g_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250k_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250k_brochure.pdf\">OKS-250K<\/a><\/td><td class=\"column-3\">Vyaire \/ Carefusion Avea<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 10 \u2013 14,5 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Ficha mini jack de 3,5 mm<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-250k_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915_brochure.pdf\">OKS-915<\/a><\/td><td class=\"column-3\">Monitor Ohmeda 4700 Oxicap<br \/>\nMonitor S\u00e9rie Ohmeda 5100<br \/>\nAnalisador de gases Ohmeda 5250 RGM<br \/>\nMonitor Ohmeda 7200<br \/>\nMonitor S\u00e9rie Ohmeda 5100<br \/>\nS\u00e9rie Ohmeda Excel e M\u00f3dulos <br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 30 \u2013 41 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Placa de circuito de 2 an\u00e9is<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-915_Brochure<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915c_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915c_brochure.pdf\">OKS-915C<\/a><\/td><td class=\"column-3\">Ventilador Drager Baby Log<br \/>\nIncubadora Dr\u00e4ger C2000<br \/>\nVentilador Drager EVITA 2<br \/>\nVentilador Drager EVITA 2<br \/>\nVentilador Drager Evita XL<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 45 \u2013 64 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Placa de circuito de 2 an\u00e9is<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915c_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-23_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\"><center><img data-recalc-dims=\"1\" decoding=\"async\" src=\"https:\/\/i0.wp.com\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915g_jpg.jpg?w=800&#038;ssl=1\" alt=\"Sensor Image\"   align=\"center\"><\/center><\/td><td class=\"column-2\"><a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915g_brochure.pdf\">OKS-915G<\/a><\/td><td class=\"column-3\">Incubadora Ohmeda Giraffe<br \/>\n<\/td><td class=\"column-4\">Sa\u00edda do sensor: 25 \u2013 35 mV<br \/>\nVida \u00fatil do sensor: &lt; 60 Meses @ 20,9% O2<br \/>\nLiga\u00e7\u00e3o el\u00e9trica: Placa de circuito de 2 an\u00e9is<br \/>\n<b>Folha de Especifica\u00e7\u00f5es:<\/b> <a href=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/oks-915g_brochure.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">OKS-915G_Brochura<\/a><br \/>\n<b>Folha MSDS:<\/b> <a href=\"https:\/\/sso2.com\/pt\/msds_medical_sensors\/\" target=\"_blank\" rel=\"noopener noreferrer\">OKS_Sensor_MSDS<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-23 from cache --><\/span><\/p><p>Verifique o equipamento OEM que possui atualmente. Se n\u00e3o encontrar uma refer\u00eancia cruzada para o seu dispositivo, envie-nos uma nota e podemos verificar a compatibilidade.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Home Southland Sensing Ltd&#8217;s Medical Oxygen Sensors. Backed with excellent customer service and an industry proven product design, leading health care providers and OEM manufacturers around the world partner with Southland Sensing Ltd. to improve sensor performance and quality while lowering their annual maintenance costs. Our team of experts carefully selects and tests each product [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-1741","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Medical Oxygen Sensors | Reliable O\u2082 Sensors for Healthcare<\/title>\n<meta name=\"description\" content=\"SSO2\u2019s medical oxygen sensors deliver accurate readings for anesthesia, ventilators, and patient monitoring systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sso2.com\/pt\/medical-oxygen-sensors\/\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Medical Oxygen Sensors\" \/>\n<meta property=\"og:description\" content=\"SSO2\u2019s medical oxygen sensors deliver accurate readings for anesthesia, ventilators, and patient monitoring systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sso2.com\/pt\/medical-oxygen-sensors\/\" \/>\n<meta property=\"og:site_name\" content=\"Southland Sensing Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-10T17:57:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tempo estimado de leitura\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sso2.com\/medical-oxygen-sensors\/\",\"url\":\"https:\/\/sso2.com\/medical-oxygen-sensors\/\",\"name\":\"Medical Oxygen Sensors | Reliable O\u2082 Sensors for Healthcare\",\"isPartOf\":{\"@id\":\"https:\/\/sso2.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/sso2.com\/medical-oxygen-sensors\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/sso2.com\/medical-oxygen-sensors\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg\",\"datePublished\":\"2021-07-30T19:50:30+00:00\",\"dateModified\":\"2025-10-10T17:57:42+00:00\",\"description\":\"SSO2\u2019s medical oxygen sensors deliver accurate readings for anesthesia, ventilators, and patient monitoring systems.\",\"breadcrumb\":{\"@id\":\"https:\/\/sso2.com\/medical-oxygen-sensors\/#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sso2.com\/medical-oxygen-sensors\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/sso2.com\/medical-oxygen-sensors\/#primaryimage\",\"url\":\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg\",\"contentUrl\":\"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sso2.com\/medical-oxygen-sensors\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sso2.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Medical Oxygen Sensors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sso2.com\/#website\",\"url\":\"https:\/\/sso2.com\/\",\"name\":\"Southland Sensing Ltd.\",\"description\":\"Industrial &amp; Medical Gas Analyzers Oxygen CO\u2082, &amp; H\u2082 Monitors\",\"publisher\":{\"@id\":\"https:\/\/sso2.com\/#organization\"},\"alternateName\":\"SSO2\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sso2.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sso2.com\/#organization\",\"name\":\"Southland Sensing Ltd.\",\"alternateName\":\"SSO2\",\"url\":\"https:\/\/sso2.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pt-PT\",\"@id\":\"https:\/\/sso2.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sso2.com\/wp-content\/uploads\/2025\/10\/sso2_300pixel.webp\",\"contentUrl\":\"https:\/\/sso2.com\/wp-content\/uploads\/2025\/10\/sso2_300pixel.webp\",\"width\":300,\"height\":50,\"caption\":\"Southland Sensing Ltd.\"},\"image\":{\"@id\":\"https:\/\/sso2.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/southland-sensing-ltd\/\"],\"description\":\"Southland Sensing Ltd. brings together superior performance, an improved user experience, and unmatched application expertise to deliver an accurate and reliable measurement solution. That\u2019s why multinationals, small companies and universities alike turn to us again and again.\",\"email\":\"sales@sso2.com\",\"telephone\":\"1-949-398-2879\",\"legalName\":\"Southland Sensing Ltd.\",\"foundingDate\":\"2013-01-01\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"11\",\"maxValue\":\"50\"},\"publishingPrinciples\":\"https:\/\/sso2.com\/contact-us\/\",\"ownershipFundingInfo\":\"https:\/\/sso2.com\/about-us\/\",\"actionableFeedbackPolicy\":\"https:\/\/sso2.com\/contact-us\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Sensores de Oxig\u00e9nio Medicinais | Sensores de O\u2082 Fi\u00e1veis \u200b\u200bpara Cuidados de Sa\u00fade","description":"Os sensores de oxig\u00e9nio medicinal da SSO2 fornecem leituras precisas para anestesia, ventiladores e sistemas de monitoriza\u00e7\u00e3o de doentes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sso2.com\/pt\/medical-oxygen-sensors\/","og_locale":"pt_PT","og_type":"article","og_title":"Medical Oxygen Sensors","og_description":"SSO2\u2019s medical oxygen sensors deliver accurate readings for anesthesia, ventilators, and patient monitoring systems.","og_url":"https:\/\/sso2.com\/pt\/medical-oxygen-sensors\/","og_site_name":"Southland Sensing Ltd.","article_modified_time":"2025-10-10T17:57:42+00:00","og_image":[{"url":"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Tempo estimado de leitura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/sso2.com\/medical-oxygen-sensors\/","url":"https:\/\/sso2.com\/medical-oxygen-sensors\/","name":"Sensores de Oxig\u00e9nio Medicinais | Sensores de O\u2082 Fi\u00e1veis \u200b\u200bpara Cuidados de Sa\u00fade","isPartOf":{"@id":"https:\/\/sso2.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/sso2.com\/medical-oxygen-sensors\/#primaryimage"},"image":{"@id":"https:\/\/sso2.com\/medical-oxygen-sensors\/#primaryimage"},"thumbnailUrl":"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg","datePublished":"2021-07-30T19:50:30+00:00","dateModified":"2025-10-10T17:57:42+00:00","description":"Os sensores de oxig\u00e9nio medicinal da SSO2 fornecem leituras precisas para anestesia, ventiladores e sistemas de monitoriza\u00e7\u00e3o de doentes.","breadcrumb":{"@id":"https:\/\/sso2.com\/medical-oxygen-sensors\/#breadcrumb"},"inLanguage":"pt-PT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sso2.com\/medical-oxygen-sensors\/"]}]},{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/sso2.com\/medical-oxygen-sensors\/#primaryimage","url":"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg","contentUrl":"https:\/\/sso2.com\/wp-content\/uploads\/2024\/03\/medical-oxygen-scaled.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/sso2.com\/medical-oxygen-sensors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sso2.com\/en\/"},{"@type":"ListItem","position":2,"name":"Medical Oxygen Sensors"}]},{"@type":"WebSite","@id":"https:\/\/sso2.com\/#website","url":"https:\/\/sso2.com\/","name":"Southland Sensing Ltd.","description":"Industrial &amp; Medical Gas Analyzers Oxygen CO\u2082, &amp; H\u2082 Monitors","publisher":{"@id":"https:\/\/sso2.com\/#organization"},"alternateName":"SSO2","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sso2.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pt-PT"},{"@type":"Organization","@id":"https:\/\/sso2.com\/#organization","name":"Southland Sensing Ltd.","alternateName":"SSO2","url":"https:\/\/sso2.com\/","logo":{"@type":"ImageObject","inLanguage":"pt-PT","@id":"https:\/\/sso2.com\/#\/schema\/logo\/image\/","url":"https:\/\/sso2.com\/wp-content\/uploads\/2025\/10\/sso2_300pixel.webp","contentUrl":"https:\/\/sso2.com\/wp-content\/uploads\/2025\/10\/sso2_300pixel.webp","width":300,"height":50,"caption":"Southland Sensing Ltd."},"image":{"@id":"https:\/\/sso2.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/southland-sensing-ltd\/"],"description":"Southland Sensing Ltd. brings together superior performance, an improved user experience, and unmatched application expertise to deliver an accurate and reliable measurement solution. That\u2019s why multinationals, small companies and universities alike turn to us again and again.","email":"sales@sso2.com","telephone":"1-949-398-2879","legalName":"Southland Sensing Ltd.","foundingDate":"2013-01-01","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"11","maxValue":"50"},"publishingPrinciples":"https:\/\/sso2.com\/contact-us\/","ownershipFundingInfo":"https:\/\/sso2.com\/about-us\/","actionableFeedbackPolicy":"https:\/\/sso2.com\/contact-us\/"}]}},"jetpack_sharing_enabled":true,"jetpack_shortlink":"https:\/\/wp.me\/PaSzwI-s5","_links":{"self":[{"href":"https:\/\/sso2.com\/pt\/wp-json\/wp\/v2\/pages\/1741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sso2.com\/pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/sso2.com\/pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/sso2.com\/pt\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/sso2.com\/pt\/wp-json\/wp\/v2\/comments?post=1741"}],"version-history":[{"count":0,"href":"https:\/\/sso2.com\/pt\/wp-json\/wp\/v2\/pages\/1741\/revisions"}],"wp:attachment":[{"href":"https:\/\/sso2.com\/pt\/wp-json\/wp\/v2\/media?parent=1741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}